Kia Soul: Cooling Fan Description
Kia Soul 2014-2019 PS Service Manual / Engine Mechanical System / Cooling System / Cooling Fan Description
[Air conditioning type]
The cooling fan operates in 2 stages (HIGH/LOW). The engine control module
(ECM) controls the cooling fan according to the coolant temperature, vehicle
speed and A/C operation.
[Cooling fan operation conditions]
A/C switch |
A/C pressure
[kgf/cm² G (psi G)] |
Vehicle speed
[km/h (mph)] |
Coolant temperature
[°C (°F)] |
Cooling fan speed |
OFF |
ㅡ |
V < 45 (28) |
95 ~ 100 (203 ~ 212) |
LOW |
100 (212) or above |
HIGH |
|||
45 (28) ≤ V < 80 (49.7) |
95 ~ 100 (203 ~ 212) |
LOW |
||
100 (212) or above |
HIGH |
|||
80 (49.7) ≤ V |
105 (221) or above |
HIGH |
||
ON |
P < 6 (85.3) |
All |
105 (221) or above |
HIGH |
6 (85.3) ≤ P < 12 (170.7) |
V < 45 (28) |
45 ~ 100 (113 ~ 212) |
LOW |
|
100 (212) or above |
HIGH |
|||
45 (28) ≤ V < 80 (49.7) |
95 ~ 100 (203 ~ 212) |
LOW |
||
100 (212) or above |
HIGH |
|||
80 (49.7) ≤ V |
105 (221) or above |
HIGH |
||
12 (170.7) ≤ P < 15.5 (120.5) |
V < 45 (28) |
-30 ~ 95 (-22 ~ 203) |
LOW |
|
95 (203) or above |
HIGH |
|||
45 (28) ≤ V < 80 (49.7) |
95 ~ 100 (203 ~ 212) |
LOW |
||
100 (212) or above |
HIGH |
|||
80 (49.7) ≤ V |
105 (221) or above |
HIGH |
||
15.5 (120.5) ≤ P |
All |
-30 (-22) or above |
HIGH |
[Non-Air conditioning type]
The cooling fan operates in 1 stages (HIGH). The engine control module
(ECM) controls the cooling fan according to the coolant temperature, vehicle
speed and A/C operation.
[Cooling fan operation conditions]
A/C switch |
A/C pressure [kgf/cm² G (psi G)] |
Vehicle speed [km/h (mph)] |
Coolant temperature [°C (°F)] |
Cooling fan speed |
OFF |
ㅡ |
V < 45 (28) |
95 ~ 100 (203 ~ 212) or above |
HIGH |
45 (28) ≤ V < 80 (49.7) |
95 ~ 100 (203 ~ 212) or above |
HIGH |
||
80 (49.7) ≤ V |
105 (221) or above |
HIGH |
Cooling Fan Components
1. Cooling fan mounting retainer 2. Torque washer 3. Cooling fan 4. Fan motor 5. Cooling fan shroud 6. Cooling fan resistor ...Cooling Fan Specifications
Item Specification Motor capacity (W) 140 (With A/C) 120 (Without A/C) Fan type Puller Puller Fan speed control ...See also:
Power Window Motor Components
...
Windshield Wiper-Washer Switch
Inspection
Check for continuity between the terminals while operating the wiper
and washer switch. If it is not normal condition, replace wiper and wiper
switch.
Wiper Switch
...
Components and Components Location
Components (1)
1. Front door pull cap
2. Front door inside handle cap
3. Front door quadrant inner cover
4. Front door trim
5. Front door belt inside weatherstrip
6. F ...