Kia Soul: Telemetics Unit (TMU) Component - MTS System - Body Electrical SystemKia Soul: Telemetics Unit (TMU) Component

Kia Soul 2014-2019 PS Service Manual / Body Electrical System / MTS System / Telemetics Unit (TMU) Component

Connector Pin Specification
No.
Pin Name
Type
From
To
Description (Wiring Spec.)
1
GND
DC Ground
TMU
Battery
Connected to battery ground
2
GND
DC Ground
TMU
Battery
Connected to battery ground
3
-
-
-
-
-
4
-
-
-
-
-
5
-
-
-
-
-
6
-
-
-
-
-
7
-
-
-
-
-
8
-
-
-
-
-
9
-
-
-
-
-
10
-
-
-
-
-
11
-
-
-
-
-
12
HS CAN (-)
Data I/O
BUS
BUS
High Speed CAN bus low
13
HS CAN (+)
Data I/O
BUS
BUS
High Speed CAN bus high
14
-
-
-
-
-
15
-
-
-
-
-
16
-
-
-
-
-
17
-
-
-
-
-
18
Battery (+)
DC Input
Battery
TMU
DC level input from battery Supply power to TMU
19
Ignition 1
Data Input
Junction Box
TMU
Vehicle Key mode status
20
ACC
Data Input
Junction Box
TMU
Vehicle Key mode status
21
Airbag
Data Input
ACU
TMU
Airbag status data from ACU
22
-
-
-
-
-
23
-
-
-
-
-
24
-
-
-
-
-
25
-
-
-
-
-
26
-
-
-
-
-
27
Speed
Data Input
-
TMU
GPS Calibration (UVO ONLY)
28
-
-
-
-
-
29
-
-
-
-
-
30
-
-
-
-
-
31
MM CAN (-)
Data I/O
BUS
BUS
Low Speed CAN bus low
32
MM CAN (+)
Data I/O
BUS
BUS
Low Speed CAN bus high

    Description
    The Vehicle Information System is a Telematics service that ensures comfortable and enjoyable driving by providing safety, security, and vehicle diagnostic information, with the option of ...

    Telemetics Unit (TMU) Removal
    1. Disconnect the negative (-) battery terminal. 2. Remove the glove box housing. (Refer to Body - "Glove Box Hou ...

    See also:

    Air cleaner
    Filter replacement It must be replaced when necessary, and should not be washed. You can clean the filter when inspecting the air cleaner element. Clean the filter by using compressed air. ...

    Installation
    1. Connect the connectors and install the BCM. 2. Install the glove box housing and audio/AVN head unit. ...

    Blower Unit Repair procedures
    Replacement     • Be sure to read and follow the “General Safety Information and Caution” before doing any work related with the high voltage system. Failu ...