Kia Soul 2014-2019 PS Service Manual / Automatic Transaxle System / Automatic Transaxle Control System / Overdrive Clutch Control Solenoid Valve(OD/C_VFS). Specifications
Direct control VFS[OD/C]
▷ Control type : Normal high type
Control Pressure kpa (kgf/cm², psi) |
500.14 ~ 9.81 (5.1 ~ 0.1, 72.54 ~ 1.42) |
Current value(mA) |
50 ~ 850 |
Internal resistance(Ω) |
5.1 |
Overdrive Clutch Control Solenoid Valve(OD/C_VFS). Description
Overdrive clutch control solenoid valve(OD/C) is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the overdrive clutch. ...See also:
Vehicle handling instructions
As with other vehicles of this type, failure to operate this vehicle correctly may result in loss of control, an accident or vehicle rollover.
Specific design characteristics (higher ground clearanc ...
Alternator Circuit Diagram
•
COM signal - When