Kia Soul: Mode Control Actuator Inspection - Heater - Heating,Ventilation And Air ConditioningKia Soul: Mode Control Actuator Inspection

Kia Soul 2014-2019 PS Service Manual / Heating,Ventilation And Air Conditioning / Heater / Mode Control Actuator Inspection

1.
Turn the ignition switch OFF.
2.
Disconnect the mode control actuator connector.
3.
Verify that the mode control actuator operates to the defrost mode when connecting 12V to terminal 3 and grounding terminal 7.
Verify that the mode control actuator operates to the vent mode when connected in reverse.

1. -
2. -
3. Defrost mode
4. Sensor ground
5. Feedback signal
6. Sensor (+ 5V)
7. Vent mode

4.
Connect the mode control actuator connector.
5.
Turn the ignition switch ON.
6.
Check the voltage between terminal 5 and 4.
Specification
Door position
Voltage (V)
Error detecting
Vent
0.3±0.15
Low voltage : 0.1V or less
High voltage : 4.9V or more
Defrost
4.7±0.15

It will feedback the current position of the actuator to controls.
7.
If the measured voltage is not within specification, substitute with a known-good mode control actuator and check for proper operation.
8.
Replace the mode control actuator if it is proved that there is a problem with it.
    Mode Control Actuator Description
    The mode control actuator is located at the heater unit. It adjusts the position of the mode door by operating the mode control actuator based on the signal of the A/C control unit. Pressing ...

    Mode Control Actuator Replacement
    [Standard Tyep] 1. Disconnect the negative (-) battery terminal. 2. Remove the crash pad lower panel. (Refer to Body - "Crash P ...

    See also:

    Brake lines, hoses and connections Inspection
    Visually check for proper installation, chafing, cracks, deterioration and any leakage Replace any deteriorated or damaged parts immediately. ...

    Input Speed Sensor. Signal Waveform
    Fig 1) Input/Output speed sensor at low speed Fig 2) Input/Output speed sensor at high speed ...

    Intake Actuator Description
    The intake actuator is located at the blower unit. It regulates the intake door by a signal from the control unit. Pressing the intake selection switch will shift between recirculation and fr ...