Smart Junction Box(SJB)
1. |
General function : Interior Junction Box + some functions
of BCM
It controls loads with CAN communication and IPS.
|
2. |
Main function
A. |
Low speed CAN communication(100 kbps)
|
B. |
Self diagnostics(Lamp open/short)
|
C. |
Fail safe(When MCU/CAN is fail, Head lamp / Tail lamp
directly drive)
|
D. |
Protection of bulb over-voltage(PWM function)
|
E. |
Cut of Over-load and Short : PCL(Program Current Limit)
|
|
Auto Cut System Of Dark Current
1. |
Description : It cuts automatically power to be provided with
load for reducing useless dark current according to vehicle state.
|
2. |
SJB had 3 modes, "Normal Mode", "Sleep Mode", "Power Off Mode".
Auto cut of dark current practice in "Sleep Mode".
A. |
"Sleep" condition : IG OFF, constant input switch,
CAN network doesn't activate.
|
B. |
"Sleep" resolutive condition : Any switch inputs,
CAN network activates, KEY ON, IGN ON
|
C. |
"Power OFF" condition : The setting time of timer
which is used by cutting a load power expires.
|
D. |
"Normal Mode" : SJB function normally activates.
|
E. |
"Sleep Mode" : It is low power mode and activates
for reducing electricity consumption of SJB or IPM. Auto
cut of dark current function activates.
|
F. |
"Power OFF Mode" : Power of MCU and circumferential
circuit is cut for minimizing electricity consumption. Operation
stops.
|
|
3. |
The explanation - The auto cut of dark current
Before delivering to customer
|
Fuse switch OFF
|
•All door close & RKE door lock or Constant switch state
(Auto cut of dark current scenario starts.)
-After "sleep" state is for 20 min.
-SJB power down(SJB dark current : 200 μA) and cutting
power of Lamp/Body Load/Wake up
|
|
After delivering to customer
|
Fuse switch ON
|
•All door close & Constant switch state : C_BAState=OFF
(Auto cut of dark current scenario starts.)
-After "sleep" state is for 20 min.
-SJB power down(SJB dark current : 200 μA) and cutting
power of Lamp Load
•In case RKE door lock : C_BAState=ON & Trunk SW=CLOSE
(Auto cut of dark current scenario starts.)
-After "Sleep" state 35s~65s (Waiting time of other
unit : 30~60s + SJB sleep counts 5s)
-SJB Powerdown(SJB dark current : 200 μA) and cutting
power of Lamp Load
|
|
|
4. |
Problem when mode switch setting is wrong
: If a fuse switch is set to OFF(Before delivering to customer)
by a customer or technician and auto cut function of dark current
activates, below problems may happen.
Symptom
|
Related part
|
•Door lock/unlock, trunk open don't activate by RKE.
(Wakeup of each module don't activate.)
|
BCM
|
•Digital clock is reset.(Memory is reset.)
|
Digital clock
|
•Setting value of audio(Volume, Frequency setting) is reset.
(Memory is reset.)
|
Audio
|
*If fuse switch OFF(before delivering to customer) is set,
power of BCM, Digital clock and audio is shut off.
|
1.
Be sure there is no play in the fuse holders, and that the
fuses are held securely.
2.
Are the fuse capacities for each ...
See also:
Oil Pressure Switch Removal and Installation
1.
Remove the under cover.
2.
Remove the oil drain plug, and drain the oil into a container.
3.
Remove the ...
Shift Lever Removal
1.
Rotating counter-clockwise shift lever knob (A).
2.
Remove the floor console assembly.
(Refer to Body - "Floor Console& ...
Outside temperature
Type A
Type B
The current outside temperature is displayed in 1°F (1°C) increments. The temperature
range is between - 40°F ~ 140°F (-40°C ~ 60°C).
The outside temperature on the dis ...