1.
Turn the ignition switch ON.
2.
Manually operate the control switch and measure the voltage of the blower motor.
3.
Select the control switch to raise the voltage until high speed.

Segment
Manual Blower Voltage (V)
A/C ON
A/C OFF
1
3.8
3.4
2
4.5
4.5
3
5.8
5.8
4
7.0
7.0
5
8.6
8.6
6
9.8
9.8
7
11.3
11.3
8
Battery (+)

1.
If the measured voltage is not within specification, substitute with a known-good field effect transistor and check for proper operation.
2.
Replace the field effect transistor if it is proved that there is a problem with it.
    Blower Resistor (Manual) Replacement
    1. Disconnect the negative (-) battery terminal. 2. Remove the glove box housing. (Refer to Body - "Glove Box Housing") ...

    Field Effect Transistor (FATC) Replacement
    1. Disconnect the negative (-) battery terminal. 2. Remove the glove box housing. (Refer to Body - "Glove Box Housing") ...

    See also:

    If engine doesn't turn over or turns over slowly
    1.If your vehicle has an automatic transaxle, be sure the shift lever is in N (Neutral) or P (Park) and the emergency brake is set. 2.Check the battery connections to be sure they are clean and tig ...

    Overhead Console Lamp Removal
    1. Disconnect the negative (-) battery terminal. 2. Remove the mounting screws (2EA). And then remove the overhead con ...

    Inspection
    Signal Circuit Inspection 1. Check ignition lock switch pull-up voltage (1) IG KEY "OFF", ENGINE "OFF". ...